Darenth MJS error codes

General Error codes

001 Temperature sensor suspect an open circuit

002 Temperature sensor suspect a short circuit

003 Boiler over temperature (98 deg or above)

004 Heater failure (failed to reach set temperature within 15 mins)

005 Microprocessor clock failure (PCB fault)

006 High water in top tank alarm (or drip tray alarm if fitted)

007 Cooler under a temperature below 0 deg (Snack Break only – Snack compartment)

008 Can’t fill boiler in time

011 Snack Break only – Temperature sensor suspect open circuit – Can compartment

012 Snack Break only – Temperature sensor suspect short circuit – Can compartment

013 Snack Break only – Cooler under temperature – Can compartment

015 Drip Tray level too high

016 Water leak detected

017 Over temperature (Feast Point only) Interface errors

020 I-Can interface error (can’t communicate with host machine)

030 MDB change-giver communication failure

040 Cashless system communication failure

050 Bill validator error

Carousel based machines

101 Can’t park cup pusher motor

102 Can’t find carousel index switch

103 Can’t find carousel home switch

104 Carousel overshoot (twice in succession)

105 Index switch found too early Ice Break

120 Can’t move the lift to the upper position (or can’t find upper position switch)

121 Can’t move the lift to a lower position (or can’t find lower position switch)

122 Can detector beam broken (when not expected to be so)

123 Can’t move the lift to a mid-position (or can’t find mid-position switch)

131 Can failed to arrive in the lift from selection 1

132 Can failed to arrive in the lift from selection 2

133 Can failed to arrive in the lift from selection 3

134 Can failed to arrive in the lift from selection 4

135 Can failed to arrive in the lift from selection 5

Refresh 700 / 1400

140 Can’t find the home switch on cup carrier

141 Can’t find index switch on cup carrier

142 Cup failed to drop from carousel into cup catcher

143 Vend stopped mid-cycle by opening main doors

144 Can’t open lift-up cup door

145 Can’t close lift-up cup door

146 Carousel column change-over motor error (Refresh1400 only)

Separator based machines (Style 5)

160 Separator (any) running for longer than 3 sec when the machine first powered up

161 Separator 1 overrun (run longer than 3 sec)

162 Separator 2 overrun (run longer than 3 sec)

163 Separator 3 overrun (run longer than 3 sec)

164 Separator 4 overrun (run longer than 3 sec)

165 Separator 5 overrun (run longer than 3 sec)

166 Separator 6 overrun (run longer than 3 sec)

167 Separator 7 overrun (run longer than 3 sec)

168 Separator 8 overrun (run longer than 3 sec)

169 Separator 9 overrun (run longer than 3 sec)

170 Separator 10 overrun (run longer than 3 sec)

181 Separator 1 failed to start (no current sensed when power applied)

182 Separator 2 failed to start

183 Separator 3 failed to start

184 Separator 4 failed to start

185 Separator 5 failed to start

186 Separator 6 failed to start

187 Separator 7 failed to start

188 Separator 8 failed to start

189 Separator 9 failed to start

190 Separator 10 failed to start

Snack Break

211 Snack vend 11 failed to start

The last 2 numbers relate to the vend number e.g. 223 is vend 23

276 Snack vend 76 failed to start Feast Point

290 Lift failed to home

291 Failed to move the lift to the required position

292 Failed to home conveyor

293 Failed to move conveyor to the required position

294 Shelf tilt mechanism failed

299 Lift/conveyor position index error – software problem

Snack Break

311 Snack vend 11 overrun error

The last 2 numbers relate to the vend number e.g. 355 is vend 55 etc.

376 Snack vend 76 overrun error

391 Shelf 1 initialising error

The last number relates to the shelf position e.g. 393 is shelf 3 etc.

398 Shelf 8 initialising error (cans)

Venetian

420 Cup station position error

421 Cup door error

423 New cup stack motor error